What MICA does for a prototype
A bench prototype brief can go through the pipeline, but MICA has no special handling for sensitive analog signals. Analog signals vary smoothly, like light level. MICA turns your brief into requirements, parts, a schematic (the map of which parts connect to which) and a netlist (the list of connections), then tries to place and route the board. The electrical rule check (ERC) tests the wiring before and after routing (drawing the copper paths). The design rule check (DRC) tests clearances, the copper ring around each hole, and any connection left unrouted. A board that fails is shown as failed and is not exported. Check noise and supply cleanliness by hand. MICA has power budget and radio link budget calculators, but the normal build does not run them yet, so that math is still yours to do.
A declared antenna keepout, an area where parts and copper are not allowed, is checked by the DRC. Firmware (the software on the chip) is a placeholder today. It compiles and passes tests on your computer against a simulated register map, and it must not be flashed to a chip. Reports record the checks that ran. They could be useful notes, but they are not a design history file, the written trail regulators ask for.
- Written record: reports of what ran and what failed
- Sensor signals: not specially handled. Review them by hand.
- Radio: declared keepouts are checked. Link budgets are not in the normal build yet.
- Changes: ask in plain words, and MICA tries again and re-runs the checks
The line MICA will not cross
Be clear about this: MICA is not for medical devices. No board has been fabricated yet. Firmware has not run on a real chip and must not be flashed. Nothing here is tested to IEC 60601, the safety standard for medical electrical equipment. Nothing is checked for biocompatibility, whether a material is safe against skin or tissue. Nothing is risk-managed under ISO 14971, the medical device risk management standard. Nothing is marked by the FDA or CE. No layout tool can do those things. The checks cover geometry and connections. They do not cover safety, efficacy (whether it works as intended) or compliance.
If you use MICA for early exploration, hand the design to qualified engineers for everything else. Never connect a MICA board to a person.
Honest limits
No MICA board has been fabricated yet. Copper-pour clearance (the gap between filled copper areas) is checked by the DRC. Only about 30 parts have checked pin data (which pin on a part does what). 3D component heights are estimated. For medical-adjacent work, treat every output as an early input to a qualified process, never as a device.